Indian Journal of Animal Research

Indian Journal of Animal Research cover
Volume 56 · Issue 7 · 2022/01/16

Development of a Universal Scale for Validating the Process of Sanitization of Equipment, Materials and Surfaces in the Animal Facility

A.S. Chernov
A.N. Minakov
E.V. Malyavina
A.S. Elfimov
G.B. Telegin
175 Views

Submitted

2021/05/18

First Online

2022/01/16

doi

10.18805/IJAR.B-1387

Cite article - A.S. Chernov, A.N. Minakov, E.V. Malyavina, A.S. Elfimov, G.B. Telegin. (2022). Development of a Universal Scale for Validating the Process of Sanitization of Equipment, Materials and Surfaces in the Animal Facility. Indian Journal of Animal Research. 56(7): 909–913. doi: 10.18805/IJAR.B-1387

Abstract

Background: Monitoring of sanitization of cage equipment is an essential function of any laboratory animal facilities, seeking to ensure the animal health and welfare. The purpose of the current study was to develop universal scale for monitoring sanitization through detection of residual ATP for the most effective process of sanitizing components of rodents micro- and macro-environment.

Methods: Sterile pens and swabs for the HY-LiTE ® Luminometer Instrument were used to measure ATP concentration (RLU) on the cleaned surface samples. We have examined the elements of the microenvironment (rodent and rabbit cage, cage wire meshes, feed separating pieces, water bottles with tips, houses, tunnels, IVC cage frames, cage tops and cage wire meshes). The assessed swab area on each of the surfaces was 10×10 cm.

Result: We observed, that combined washing (cleaned manually and with automatic universal washers with detergent) gives the lowest RLU values. Monitoring of the quality of sanitization of equipment and surfacescan be carried out without the use of microbiological tests. Use of pre-washing allows increasing the service life of caging equipment. We have developed an assessment scale to monitor sanitizing, which can be recommended to scientific and breeding animal facilities for monitoring sanitization cage equipments.

Acknowledgement

true

References

  1. Boyce, J.M., Havill, N.L., Dumigan, D.G., Golebiewski, M., Balogun, O. and Rizvani, R. (2009). Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infection Control and Hospital Epidemiology. 30(7): 678-84. Bruch, M.K. and Smith, F.W. (1968). Improved method for pouring RODAC plates. Applied Microbiology. 16(9): 1427-28. Dancer, S.J. (2014). Controlling hospital-acquired infection: Focus on the role of the environment and new technologies for decontamination. Clinical Microbiology. 27: 665-690. Ednie, D.L., Wilson, R.P., Max Lang, C. (1998). Comparison of two sanitation monitoring methods in an animal research facility. Contemporary Topics in Laboratory Animal Science. 37(6): 71-74. Gaylarde, C.C., Bento, F.M., Kelley, J. (1999). Microbial contamination of stored hydrocarbon fuels and its control. Revista de Microbiología. 30: 1-10. Grace, S.A., Munday, K.A. and Noble, A.R. (1979). Sodium, potassium and water metabolism in the rabbit: the effect of sodium depletion and repletion. Journal of Physiology. 292: 407-20. Gunther, R.A. and Rabinowitz, L. (1980). Urea and renal concentrating ability in the rabbit. Kidney International. 17: 205-22. Hacek, D.M., Trick, W.E., Collins, S.M., Noskin, G.A. and Peterson, L.R. (2000). Comparison of the Rodac imprint method to selective enrichment broth for recovery of vancomycin- resistant enterococci and drug-resistant Enterobacteriaceae from environmental surfaces. Journal of Clinical Microbiology. 38(12): 4646-8. Handbook of Hygiene Control in the Food Industry, (2005). Handbook of hygiene control in the food industry Edited by Lelieveld, H.M., Mostert, M.A., Holah J. Published in North America by CRC Press LLC. (2005). 720 p. Hart, J.B., French, M.L., Eitzen, H.E. and Ritter, M.A. (1973). RODAC plate-holding device for sampling surfaces during surgery. Applied Microbiology. 26(3): 417-18. Horn, M.J., Hudson, S.V., Bostrom, L.A. and Cooper, D.M. (2012). Effects of cage density, sanitation frequency and bedding type on animal wellbeing and health and cage environment in mice and rats. Journal of the American Association for Laboratory Animal Science. 51(6): 781-88. Mulvey, D., Redding, P., Robertson, C., Woodall, C., Kingsmore, P., Bedwell, D. and Dancer, S.J. (2011). Finding a benchmark for monitoring hospital cleanliness. Journal of Hospital Infection. 77(1): 25-30. Nante, N., Ceriale, E., Messina, G., Lenzi, D. and Manzi, P. (2017). Effectiveness of ATP bioluminescence to assess hospital cleaning: A review. Journal of Preventive Medicine and Hygiene. 58(2): E177-E183. National Research Council (US) (2011). Committee for the Update of the Guide for the Care and Use of Laboratory Animals. Guide for the Care and Use of Laboratory Animals (The Guide). 8 th edition. Washington (DC): National Academies Press (US). National Research Council (US) (1995). Subcommittee on Laboratory Animal Nutrition. Nutrient Requirements of Laboratory Animals: Fourth Revised Edition, Washington (DC): National Academies Press (US); (1995). 5, Nutrient Requirements of the Hamster. Available from: https://www.ncbi.nlm.nih.gov/books/NBK231928 . Rauch, M.E., Graef, H.W., Rozenzhak, S.M., Jones, S.E., Bleckmann, C.A., Kruger, R.L. and Stone, M.O. (2006). Characterization of microbial contamination in United States Air Force aviation fuel tanks. Journal of Industrial Microbiology and Biotechnology. 33(1): 29-36. Saren, L.E., Hammarberg, L.K., Kastenmayer, R.J. and Hallengren, L.C. (2016). Developing a performance standard for adequate sanitization of wire-bar lids. Journal of the American Association for Laboratory Animal Science. 55(6): 765-68. Schondelmeyer, C.W., Dillehay, D.L., Webb, S.K., Huerkamp, M.J., Mook, D.M. and Pullium, J.K. (2006). Investigation of appropriate sanitization frequency for rodent caging accessories: evidence supporting less-frequent cleaning. Journal of the American Association for Laboratory Animal Science. 45(6):40-3. Shama, G. and Malik, D. (2013). The uses and abuses of rapid bioluminescence-based ATP assays. International Journal of Hygiene and Environmental Health. 216: 115-125. Sharapova, T.N., Romanova, E.A., Chernov, A.S., Minakov, A.N., Kazakov, V.A., Kudriaeva, A.A., Belogurov, A.A.Jr, Ivanova, O.K., Gabibov, A.G., Telegin, G.B., Yashin, D.V., Sashchenko, L.P. (2021). Protein PGLYRP1/Tag7 peptides decresases the proinflammatory response in human blood cell and mouse model of diffuse alveolar damage of lung through blockage of the TREM-1 and TNFR1 receptors. Int J Mol Sci. 18; 22(20):11213. Sherlock, O., O’Connell, N., Creamer, E. and Humphreys, H. (2009). Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness. Journal of Hospital Infection. 72: 140-46. Smith, B.J., Killoran, K.E., Xu, J.J., Ayers, J.D. and Kendall, L.V. (2018). Extending the use of disposable caging based on results of microbiologic surface testing. Journal of the American Association for Laboratory Animal Science. 57(3): 253-57. Srinivasan, S., Kaplan, C.N. and Mahadevan, L. (2019). A multiphase theory for spreading microbial swarms and films. Elife. 8: e42697. Telegin, G.B., Minakov, A.N., Chernov, A.S., Kazakov, V.A., Kalabina, E.A., Manskikh, V.N., Asyutin, D.S., Belogurov, A.A. Jr, Gabibov, A.G., Konovalov, N.A., Spallone, A. (2021). A New Precision Minimally Invasive Method of Glial Scar Simulation in the Rat Spinal Cord Using Cryoapplication Front Surg. 15(8): 607551. Turner, D.E., Daugherity, E.K., Altier, C. and Maurer, K.J. (2010). Efficacy and limitations of an ATP-based monitoring system. Journal of the American Association for Laboratory Animal Science. 49(2):190-5. Vilar, M.J., Rodriguez-Otero, J.L., Dieguez, F.J., Sanjuan, M.L., Yus, E. (2008). Application of ATP bioluminescence for evaluation of surface cleanliness of milking equipment. International Journal of Food Microbiology. 125: 357-361. Whiteley, G.S., Glasbey, T.O. and Fahey, P.P. (2016). A suggested sampling algorithm for use with ATP testing in cleanliness measurement. Infection, Disease and Health. 21(4): 169-75.
EDITORIAL BOARD

Guided by Experienced Academic Leadership

Distinguished scholars and subject experts committed to editorial excellence, scientific integrity and rigorous peer review.

View Full Board
Yashpal Singh Malik
Chief Editor

Yashpal Singh Malik

Deputy Director General (Agricultural Education)Indian Council of Agricultural Research, Headquarters, New Delhi , India

L.D. Singla
Associate chief editor

L.D. Singla

Professor and HeadAbhilashi University, Chachyot, Himachal Pradesh, India

Vilas G. Atkare
Editor

Vilas G. Atkare

DeanDr. Panjabrao Deshmukh Krishi Vidyapeeth, Akola, Krishi Nagar, Maharashtra, India

S. Maya
Editor

S. Maya

Associate Dean and Professor & HeadKerala Veterinary and Animal Sciences University, Mannuthy, Thrissur, Kerala, India