Indian Journal of Animal Research

Indian Journal of Animal Research cover
Volume 56 · Issue 10 · 2021/03/01

Studies on Pulsed-wave Doppler Echocardiographic Parameters of Blood Flow through Mitral, Tricuspid and Aortic Valves in Healthy Indian Spitz Dogs

Deepti Bodh
Mozammel Hoque
Abhishek Chandra Saxena
291 Views

Submitted

2020/07/21

First Online

2021/03/01

doi

10.18805/IJAR.B-4256

Cite article - Deepti Bodh, Mozammel Hoque, Abhishek Chandra Saxena. (2021). Studies on Pulsed-wave Doppler Echocardiographic Parameters of Blood Flow through Mitral, Tricuspid and Aortic Valves in Healthy Indian Spitz Dogs. Indian Journal of Animal Research. 56(10): 1246–1251. doi: 10.18805/IJAR.B-4256

Abstract

Background: Pulsed-wave Doppler measures blood flow at specific point and provides information on velocity, direction and uniformity of blood flow throughout cardiac cycle. Till date, there is no published data on study of cardiac parameters using pulsed-wave Doppler echocardiography in Indian Spitz dogs.

Methods: Twenty-four clinically normal Indian Spitz dogs were subjected to pulsed-wave Doppler echocardiography to determine the reference intervals for Doppler parameters of blood flow through mitral, tricuspid and aortic valves. Mitral peak E and A-wave velocities, E/A ratio, deceleration time, isovolumic relaxation time, E and A-wave velocity time integral, E duration and A duration were 0.69±0.09 m/s, 0.43±0.12 m/s, 1.69±0.45, 111.25±35.94 ms, 48.50±24.77 ms, 0.07±0.01 m and 0.04±0.02 m, 196.88±44.38 ms and 181.25±64.89 ms, respectively. Tricuspid peak E and A-wave velocities, E/A ratio and E and A-wave velocity time integral were 0.57±0.11 m/s, 0.38±0.08 m/s, 1.56±0.32 and 0.07±0.02 m and 0.05±0.01 m, respectively. Aortic peak velocity, velocity time integral and ejection time were 0.87±0.07 m/s, 0.11±0.02 m and 0.25±0.04 s, respectively.

Conclusion: The reference values of flow parameters across mitral, tricuspid and aortic valves using pulsed-wave Doppler echocardiography were determined. Mitral, tricuspid and aortic valve flow variables were unaffected by gender whereas isovolumic relaxation correlated positively with body weight.

Acknowledgement

true

References

  1. Bodh, D., Hoque, M. and Saxena, A.C. (2020). Pulsed wave Doppler echocardiographic evaluation of mitral, tricuspid and aortic valve flows in healthy Indian mongrel dogs. Indian Journal of Veterinary Surgery. 41: 6-10. Boon, J. (2011). Evaluation of size, function and hemodynamics. In: Veterinary echocardiography. (Boon, J. Ed.), 2 nd ed., Wiley-Blackwell, Chichester, pp. 153-247. Brown, D.J., Knight, D.H. and King, R.R. (1991). Use of pulse-wave Doppler echocardiography to determine aortic and pulmonary velocity and flow variables in clinically normal dogs. American Journal of Veterinary Research. 52: 543-550. Cavalcanti, G.A.O., Muzzi, R.A.L., Araujo, R.B. and Cherem, M. (2007). Doppler echocardiographic assessment of diastolic function in Boxer dogs. Arquivo Brasileiro de Medicina Veterinária e Zootecnia. 59: 1169-1176. Darke, P.G.G., Fuentes, V.L. and Champion, S.R. (1993). Doppler echocardiography in canine congestive cardiomyopathy. In: Proc.11 th ACVIM, p 531-534. Jeyaraja, K., Yamini, H.S. and Thirunavakkarasu, P.S. (2016). Pulsed Wave Doppler and Color Flow Doppler Evaluation in Healthy Dogs and Dogs with Cardiac Disease. International Journal of Advanced Veterinary Science and Technology. 5: 256-265. Kirberger, R.M., Van Den Berg, P.B., Daradz, B. (1992a). Doppler echocardiography in the normal dog: Part I. Velocity findings and flow patterns. Veterinary Radiology and Ultrasound. 33: 370-379. Kirberger, R.M., Van Den Berg, P.B., Grimbeek, R.J. (1992b). Doppler echocardiograpy in the normal dog: Part II. Factors influencing blood flow velocities and a comparison between left and right heart flows. Veterinary Radiology and Ultrasound. 33: 380-386. Kobal, P. and Petric, A.D. (2007). Echocardiographic diastolic indices of left ventricle in normal Doberman Pinschers and Retrievers. Slovenian Veterinary Research. 44: 31-40. Muzzi, R.A.L., Muzzi, L.A.L., de Araujo, R.B. and Cherem, M. (2006). Echocardiographic indices in normal German shepherd dogs. Journal of Veterinary Science. 7: 193-198. O’Sullivan, M.L., O’Grady, M.R. and Minors, S.L. (2007). Assessment of diastolic function by Doppler echocardiography in normal Doberman Pinschers and Doberman Pinschers with dilated cardiomyopathy. Journal of Veterinary Internal Medicine. 21: 81-91. Pereira, G.G., Santos, L.C., Yamaki, A.L.F. and Larsson, M.H.M.A. (2009). Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler. Pesquisa Veterinaria Brasileira. 29: 291-294. Schober, K.E., Fuentes, V.L., Mc Ewan, J.D. and French, A.T. (1998). Pulmonary venous flow characteristics as assessed by transthoracic pulsed Doppler echocardiography in normal dogs. Veterinary Radiology and Ultrasound. 39: 33-41. Schober, K.E. and Fuentes, V.L. (2001). Effects of age, body weight and heart rate on transmitral and pulmonary venous flow in clinically normal dogs. American Journal of Veterinary Research. 62: 1447-1454. Schober, K.E., Fuentes, V.L., Baade, H. and Oechtering, G. (2002). Echokardiographische referenzwerte beim Boxer. Tierarztliche Praxis. 30: 417-426. Vajhi, A.R., Mirshahi, A., Dezfouli, M.R.M., Mosoudifard, M., Veshkini, A., Sorouri, S., Torki, E., Azizzadeh, M., Ghiadi, A.J. (2013). Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran. Iranian Journal of Veterinary Research. 14: 42-49. Yamamoto, K., Masuyama, T., Tanouchi, J., Doi, Y., Kondo, H., Hori, M., Kitabatake, A. and Kamada, T. (1993). Effects of heart rate on the left ventricular filling dynamics: assessment from simultaneous recordings of pulsed Doppler transmitral flow velocity pattern and haemodynamic variables. Cardiovascular Research. 27: 935-941.
EDITORIAL BOARD

Guided by Experienced Academic Leadership

Distinguished scholars and subject experts committed to editorial excellence, scientific integrity and rigorous peer review.

View Full Board
Yashpal Singh Malik
Chief Editor

Yashpal Singh Malik

Deputy Director General (Agricultural Education)Indian Council of Agricultural Research, Headquarters, New Delhi , India

L.D. Singla
Associate chief editor

L.D. Singla

Professor and HeadAbhilashi University, Chachyot, Himachal Pradesh, India

Vilas G. Atkare
Editor

Vilas G. Atkare

DeanDr. Panjabrao Deshmukh Krishi Vidyapeeth, Akola, Krishi Nagar, Maharashtra, India

S. Maya
Editor

S. Maya

Associate Dean and Professor & HeadKerala Veterinary and Animal Sciences University, Mannuthy, Thrissur, Kerala, India