Indian Journal of Animal Research

Indian Journal of Animal Research cover
Volume 58 · Issue 11 · 2021/12/18

A 3R’s Research: Rapid Assessment of New Indigenously Made Ventilators in Acute Respiratory Distress Syndrome (ARDS) Induced Rabbits by Non-invasive Method

M. Jayanthi
Ghadevaru Sarathchandra
M. Chandrasekar
M.G. Mohamad Ali
D. Balasubramanyam
S.P. Preetha
P. Satheeshkumar
101 Views

Submitted

2021/06/22

First Online

2021/12/18

doi

10.18805/IJAR.B-4687

Cite article - M. Jayanthi, Ghadevaru Sarathchandra, M. Chandrasekar, M.G. Mohamad Ali, D. Balasubramanyam, S.P. Preetha, P. Satheeshkumar. (2021). A 3R’s Research: Rapid Assessment of New Indigenously Made Ventilators in Acute Respiratory Distress Syndrome (ARDS) Induced Rabbits by Non-invasive Method. Indian Journal of Animal Research. 58(11): 1933–1940. doi: 10.18805/IJAR.B-4687

Abstract

Background: Laboratory animal models were frequently used to assess the efficiency of newly made ventilators. Assessment of efficiency of these ventilators may be useful for human patients affected with respiratory distress or COVID-19.

Methods: Rabbits were randomly divided into four groups viz ., negative control, positive control (ARDS induced), induced ARDS and co-treated with referral ventilator (VR), ARDS induced and co-treated with experimental ventilator (VE). The groups were assessed by measuring the BGA, vitals, tidal volume (VT) and other ventilator parameters.

Result: SpO 2 of control group (98.75±0.25) did not reveal any significant difference with VR -1 hr (97.75±0.63), VR-3 hrs (97.75±0.95), VE-1 hr (96.75±1.11) and VE-3hrs (97.25±0.85). While comparing with other groups, ARDS group (61±7.69) revealed a highly significant decrease (p<0.01) in the SpO 2 level. PEEP of control and other groups were found to be equal (4±0.00).

Acknowledgement

true

References

  1. Al Otaibi, H.M., Ansari, K.A., Farooqi, F.A. (2019). Evaluation of mechanical ventilators’ accuracy in clinical settings: A quality control study. Saudi Critical Care Journal. 3: 123-8. Bohlin, K., Bouhafs, R.K., Jarstrand, C., Curstedt, T., Blennow, M., Robertson, B. (2005). Spontaneous breathing or mechanical ventilation alters lung compliance and tissue association of exogenous surfactant in preterm newborn rabbits. Pediatric Research. 57(5): 624-630. Cross, L. and Matthay, A. (2011). Biomarkers in acute lung injury: insights into the pathogenesis of acute lung injury. Critical Care Clinics. 27(2): 355-77. Christoph, S. and Carsten, L. (2015). Regulation of cardiac output in hypoxia. Scandinavian Journal of Medicine and Science in Sports. 25(4): 53-59. Dellac&agrave;, R. and Farr&eacute;, R. (2009). Non-invasive Ventilation: The Impact of Machine Choice. The Buyer’s Guide to Respiratory Care Products. Pp. 30-39. Dukic, L., Milevoj Kopcinovic, L., Dorotic, A. Barsic, I. (2016). Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochemia Medica. 26(3): 318-36. Fan, E., Brodie, D., Slutsky, S. (2018). Acute Respiratory Distress Syndrome: Advances in Diagnosis and Treatment. JAMA. 319(7): 698-710. Govoni, L., Dellaca, R.L., Pe&ntilde;uelas, O., Bellani, G., Artigas, A., Ferrer, M., Navajas, D., Pedotti, A. and Farr&eacute;, R. (2012). Actual performance of mechanical ventilators in ICU: A multicentric quality control study. Medical Devices (Auckland, NZ). 5: 111. Krimsky, W., Mroz, B., McIlwaine, K., Surgenor, D., Christian, D., Corwin, L., Houston, D., Robison, C., Malayaman, N. (2009). A model for increasing patient safety in the intensive care unit: Increasing the implementation rates of proven safety measures. BMJ Quality and Safety. 18(1): 74-80. Kollef, M. and Micek, T. (2010). Using protocols to improve patient outcomes in the intensive care unit: focus on mechanical ventilation and sepsis. Seminars in Respiratory and Critical Care Medicine. 31(1): 19-30. Kosutova, P., Mikolka, P., Kolomaznik, M., Balentova, S., Adamkov, M., Calkovska, A. and Mokra, D. (2018). Reduction of lung inflammation, oxidative stress and apoptosis by the PDE4 inhibitor roflumilast in experimental model of acute lung injury. Physiological Research. 67: S645-S654. Lord, B., Boswood, A. and Petrie, A. (2010). Electrocardiography of the normal domestic pet rabbit. Veterinary Record. 167(25): 961-965. Mirabella, L., Grasselli, G., Haitsma, J.J., Zhang, H., Slutsky, A.S, Sinderby, C., Beck, J. (2014). Lung protection during non- invasive synchronized assist versus volume control in rabbits. Critical Care. 18(1): 1-3. Mullhaupt, D., Wenger, S., Kircher, P., Pfammatter, N., Hatt, J.M., Ohlerth, S. (2017). Computed tomography of the thorax in rabbits: a prospective study in ten clinically healthy New Zealand White rabbits. Acta Veterinaria Scandinavica. 59(1): 72. Rotta, A., Gunnarsson, B., Hernan, L., Fuhrman, B., Steinhorn, D. (1999). Partial liquid ventilation influences pulmonary histopathology in an animal model of acute lung injury. Journal of Critical Care. 14(2): 84-92.
EDITORIAL BOARD

Guided by Experienced Academic Leadership

Distinguished scholars and subject experts committed to editorial excellence, scientific integrity and rigorous peer review.

View Full Board
Yashpal Singh Malik
Chief Editor

Yashpal Singh Malik

Deputy Director General (Agricultural Education)Indian Council of Agricultural Research, Headquarters, New Delhi , India

L.D. Singla
Associate chief editor

L.D. Singla

Professor and HeadAbhilashi University, Chachyot, Himachal Pradesh, India

Vilas G. Atkare
Editor

Vilas G. Atkare

DeanDr. Panjabrao Deshmukh Krishi Vidyapeeth, Akola, Krishi Nagar, Maharashtra, India

S. Maya
Editor

S. Maya

Associate Dean and Professor & HeadKerala Veterinary and Animal Sciences University, Mannuthy, Thrissur, Kerala, India